The MC/S setup instructions are very similar to MPIO, detail steps are in the following. For the target
side setting, the steps are exactly the same as MPIO. Please refer to Figure E.1 to Figure E.9.
• Create a VG with RAID 5, using 3 HDDs.
• Create a UDV by using RAID 5 VG.
• Run Microsoft iSCSI initiator 2.0 and check the Initiator Node Name.
Attaching LUN to R5 UDV. Input the Initiator Node Name in Host eld.
• The volume con g setting is done.
• Check iSCSI settings. The IP address of iSCSI data port 0 is 192.168.11.229, port 1 is
192.168.12.229 for example.
Add Target Portals on Microsoft iSCSI initiator 2.0.
• Input the IP address of iSCSI data port 0 (192.168.11.229 as mentioned in previous pages).
For MC/S, there is only ONE “Target Portals” in the “Discovery” tab.
Figure E.24
RAID Introduction 77